Canada and international

Data verification and assurance for building energy, water and emissions

On this page
  1. Verification, assurance and internal review
  2. The frameworks
  3. Which programs require or reward it
  4. Step by step: preparing for verification
  5. Common mistakes
  6. How BrickFlow helps

More building owners are being asked to show that their energy, water and emissions numbers have been checked by someone independent. Ontario’s Energy and Water Reporting and Benchmarking (EWRB) program asks for it from buildings of 100,000 sq ft and larger, Quebec’s new mandatory building declaration requires it at least every four years, and GRESB scores it. Investors and lenders ask for it in their own questionnaires.

This guide is for owners, property managers and sustainability leads in Canada who need to understand what is being asked of them. It explains the words that get mixed up, the standards a verifier or assurance practitioner works to, which programs require or reward an external check, and how to prepare a portfolio so the engagement goes smoothly.

Verification, assurance and internal review

Three different activities are often described with the same words.

Internal review is a check you, your team or a tool you use performs on your own data: comparing reported totals to bills, looking for missing months, confirming floor areas. It improves quality and is the best preparation for an external check, but it ends in no independent conclusion. It does not satisfy a program that asks for verification or assurance.

Verification is an independent check of a statement, such as a GHG inventory or a benchmarking report, against stated criteria. In GHG work, ISO 14064-3 is the main verification standard; it deals with historical data, while validation deals with forward-looking claims. Canadian building programs use “verification” in a narrower, program-specific sense: in Ontario EWRB and Quebec, it means a qualified professional checks the reported data before it is submitted. What counts as a qualified professional is set by each program.

Assurance is an engagement performed under an assurance standard, such as ISAE 3000 (Revised), that ends in a formal conclusion for the people who will rely on the information. It comes in two levels:

Aspect Limited assurance Reasonable assurance
Form of conclusion Negative: based on the procedures performed, nothing has come to the practitioner’s attention that the information is materially misstated Positive: an opinion that the information is fairly stated against the criteria
Work involved Fewer or less extensive procedures More procedures, including a fuller understanding of internal controls
Remaining risk Higher than reasonable, but still meaningful Reduced to an acceptably low level
Materiality Same as reasonable Same as limited

ISO 14064-3 also has requirements and guidance on levels of assurance, so a GHG verification statement can be issued at a limited or reasonable level.

A reporting standard is not an assurance standard. The GHG Protocol Corporate Standard and ISO 14064-1 tell you how to build an inventory: boundaries, scopes, calculation methods. ISO 14064-3, ISAE 3000, ISAE 3410 and ISSA 5000 tell someone else how to check it. The GHG Protocol itself says the Corporate Standard “does not currently require any form of verification or assurance”; its Chapter 10 gives guidance only.

BC’s public sector program shows how the layers fit together. Each organization’s management reviews its data and submits a self-certification checklist; the province then has a third-party verifier review a selection of reports. Self-certification is internal review; the third-party review is verification.

The frameworks

Framework What it is Who issues it Typically used for
ISO 14064-1:2018 Specification for quantifying and reporting an organization’s GHG emissions and removals ISO Building the inventory that is later verified (a reporting standard, not a checking one)
ISO 14064-3:2019 Specification with guidance for verification and validation of GHG statements, with requirements on levels of assurance ISO Independent verification of an organization’s GHG inventory
ISO 14065:2020 Principles and requirements for bodies that validate and verify environmental information ISO The basis for accrediting verification bodies
ISO 14066:2023 Competence requirements for validation and verification teams and independent reviewers ISO Setting what a verification team must know and be able to do
ISAE 3000 (Revised) Assurance engagements other than audits or reviews of historical financial information; defines limited and reasonable assurance IAASB Assurance on sustainability data, including energy and water
ISAE 3410 Assurance engagements on GHG statements IAASB GHG assurance; withdrawn with effect from 15 December 2026
ISSA 5000 General requirements for sustainability assurance engagements, limited and reasonable, for accountants and other practitioners IAASB Sustainability assurance for periods beginning on or after 15 December 2026
CSAE 3000 and CSAE 3410 Canadian equivalents of ISAE 3000 and ISAE 3410 Auditing and Assurance Standards Board (AASB), Canada Canadian assurance engagements; the AASB has voted to withdraw CSAE 3410
CSSA 5000 Canadian standard on sustainability assurance, based on ISSA 5000 AASB, Canada Canadian sustainability assurance for periods beginning on or after 15 December 2027
AA1000AS v3 Assurance standard that evaluates adherence to the AccountAbility Principles (inclusivity, materiality, responsiveness, impact) AccountAbility Sustainability report assurance by AccountAbility-licensed providers
GHG Protocol Corporate Standard Accounting and reporting standard for corporate GHG inventories GHG Protocol Building the inventory; it does not require verification

What is changing

The IAASB published ISSA 5000 in November 2024. It is effective for periods beginning on or after 15 December 2026, and ISAE 3410 is withdrawn from that date.

In Canada, the AASB approved CSSA 5000 in March 2026 and issued it in the CPA Canada Handbook – Assurance in May 2026. It applies to periods beginning on or after 15 December 2027, with earlier application permitted. When approving it, the AASB voted to withdraw CSAE 3410. FRAS Canada’s page does not state when that withdrawal takes effect, so ask your practitioner which standard they will use for your reporting year.

Which programs require or reward it

Program What it asks for Who can do it How often
Ontario EWRB Buildings of 100,000 sq ft and larger must have a certified professional verify reported information before submitting; voluntary below that size In-house staff or third-party professionals qualified to verify energy, water, gross floor area and building characteristics, with accreditation or certification from a recognized organization in Canada or the United States The first year your report is required, then every five years
Quebec mandatory declaration The declaration must be verified by a recognized professional, and the verification report is sent with the declaration Members of the orders of administrateurs agréés, architectes, comptables professionnels agréés, évaluateurs agréés, ingénieurs, or technologues professionnels du Québec At least once every four years
City of Toronto Buildings of 9,290 m² (100,000 sq ft) and larger include an attestation by a certified professional verifying the reported information (guide) Certified professionals on the City’s list, such as professional engineers, registered architects and Certified Energy Managers The first year the building must report, then every fifth year
BC public sector Every provincial public sector organization publishes an annual Climate Change Accountability Report; management self-certifies, and the Climate Action Secretariat engages a third-party verifier to review selected organizations’ GHG reporting A third-party verifier engaged by the province Each year, for a selection of organizations; keep records for seven years
GRESB Real Estate Optional but scored: indicators MR1 to MR4 cover external review of energy (1.75 points), GHG (1.25), water (1.25) and waste (1.25) data A third party working to a recognized scheme for “verified” or “assured” Each assessment year

A few details matter for planning.

  • Ontario lists example accrediting bodies and credentials on its reporting guide, including ASHRAE, BOMI International, the Ontario Building Envelope Council, Certified Energy Auditor, Certified Measurement and Verification Professional, Professional Engineers of Ontario and Portfolio Manager certifications. Reports are filed through ENERGY STAR Portfolio Manager by 1 July.
  • Quebec’s first declaration is due by 30 June 2027 for buildings of 5,000 m² and more that are not exclusively residential, residential buildings with 50 or more units, and buildings over 100 m² owned by a public body other than a municipal body. From 2028 it extends to buildings of 2,000 m² and more and to 25 or more units, which first declare by 30 June 2028. The verification is required once in each four-year period, so the first declaration does not have to be the verified one; confirm your timing with the Ministère before you plan. See our Quebec guide.
  • GRESB offers three levels of external review in MR1 to MR4: externally checked, externally verified and externally assured, and it treats verification and assurance equally. The score depends on the option chosen and on whether reviewers accept your evidence. The evidence must show the review covers the data you reported, name the standard used and show the reviewer’s independence. GRESB’s 2026 scheme list includes ISO 14064-3, ISAE 3000, ISAE 3410, ISSA 5000, CSAE 3000 and the AA1000 Assurance Standard. CSAE 3410 and CSSA 5000 are not on it, so check with GRESB before relying on a Canadian-only standard. New schemes must be submitted for review by 15 March.

Step by step: preparing for verification

  1. Confirm what you need. For each building, list which program asks for verification or assurance, for which reporting year, by when, and who is allowed to do it. An EWRB verification by a qualified in-house staff member is a different engagement from a GRESB-recognized assurance under ISAE 3000.
  2. Set the boundary. Record which buildings are in scope, your ownership share and dates, whether you report the whole building or base building only, which utilities and emission scopes are included, and the reporting period. A verifier checks your data against your own stated boundary, so write it down.
  3. Build a data inventory. List every meter and utility account for each building, what it serves (common areas, tenant space, a central plant), its unit (kWh, m³, GJ), and where its data comes from. Include gross floor area and its source, and the occupancy and use details the program asks for.
  4. Gather source documents. Keep the utility bills or statements, Green Button or interval files, tenant submeter reads, waste hauler reports and the drawings or leases that support floor area. For emissions, record which emission factors you used and where they come from.
  5. Document every estimate. For each gap, note the period, the method and the reason. Follow the program’s own rules: GRESB, for example, limits estimates to 20% of the period with actual data and three months across both years, does not allow prior-year substitution or generic benchmarks, and asks you to disclose the method and share.
  6. Keep an audit trail. Record who entered, changed and approved each figure, and when. Keep the evidence for as long as the program asks; BC’s public sector guidance, for example, sets seven years.
  7. Run your own review first. Reconcile annual totals to bills, look for missing or duplicated months, unit and multiplier errors, meters counted twice, and floor areas that change between years without a reason. Fix what you find before the verifier does.
  8. Choose the verifier or practitioner. Match the qualification to the program: an EWRB-accepted credential, a member of one of Quebec’s six orders, or a provider working to a scheme GRESB recognizes. Confirm their independence from the people who prepared the data.
  9. Agree scope and level in writing. Name the buildings, data types, years, standard, level of assurance (limited or reasonable), the deliverable (statement, letter or report) and the date you need it. Leave time before the program deadline for corrections.
  10. Support the engagement. Assign one person to answer queries, share the inventory and source documents in an organized way, and track each request to closure.
  11. Respond to findings. Correct errors in the reporting tool, keep a record of what changed and why, and get the final statement or report only after corrections are made.
  12. File and plan the next cycle. Submit the verification result where the program asks for it, such as with Quebec’s declaration or as evidence in the GRESB portal. Diary the next required check: five years later for EWRB, within four years for Quebec, each year for GRESB.

Common mistakes

  • Treating internal review as verification. Self-checks, consultant reviews without a stated standard, and software checks are useful, but none of them is the independent check a program requires.
  • Mixing up reporting and assurance standards. Saying an inventory “follows the GHG Protocol” says nothing about whether anyone checked it.
  • Booking the verifier too late. Engagements need source documents, queries and corrections. Starting weeks before 30 June or 1 July leaves no room to fix findings.
  • An unstated boundary. If ownership share, base building versus tenant space, or the reporting period is not written down, the verifier cannot test against it.
  • Undocumented estimates. An estimate without a method and a reason is hard to defend and, under GRESB rules, can cost you coverage.
  • Evidence that does not match the submission. For GRESB, a statement that covers a different year, a different set of assets or no named standard may be only partly accepted or rejected.
  • Choosing a provider the program does not accept. Check the program’s credential or scheme list before you sign.

How BrickFlow helps

BrickFlow keeps one reviewed record per building: meters, bills, Green Button and other files you provide, floor areas, estimates and an audit trail of every change, so you can hand a verifier an organized package. BrickFlow’s own review checks your data against those sources. It is not verification or assurance, it does not satisfy the verification requirement of EWRB, Quebec or any other program, and it earns no GRESB points; you still need the qualified professional or assurance practitioner each program requires.

Sources

  1. Ontario: Report energy and water use for large buildings
  2. Québec: Déclaration obligatoire de la consommation énergétique des grands bâtiments
  3. IAASB: ISAE 3000 (Revised), Assurance Engagements Other than Audits or Reviews of Historical Financial Information
  4. ISO 14064-3:2019, Verification and validation of greenhouse gas statements
  5. GHG Protocol: Corporate Standard survey summary (2024)
  6. City of Toronto: Energy and water reporting for buildings
  7. BC: Quality assurance and quality control guidance for public sector GHG reporting (January 2026)
  8. ISO 14064-1:2018, Organization-level GHG quantification and reporting
  9. ISO 14065:2020, Bodies validating and verifying environmental information
  10. ISO 14066:2023, Competence requirements for validation and verification teams
  11. IAASB: Assurance on a greenhouse gas statement (ISAE 3410)
  12. IAASB: Understanding ISSA 5000
  13. IAASB: ISSA 5000 and assurance, core elements of building trust (November 2024)
  14. FRAS Canada: Sustainability assurance (CSSA 5000)
  15. AccountAbility: AA1000 Assurance Standard
  16. Ontario: Guide to energy and water reporting, information you need for reporting
  17. BC: Climate Change Accountability Reports
  18. GRESB: 2026 Real Estate scoring document
  19. GRESB: MR1 External review of energy data (2026)
  20. GRESB: Assurance and verification schemes
  21. GRESB: 2026 estimation rules

This guide is for orientation only and is not legal advice. Requirements depend on each building’s size, type and location, and programs change: confirm the details on the regulator’s own pages before you file.

Keep every building ready before the deadline

BrickFlow keeps one reviewed record for each building, so the data for each program is complete and traceable when you file.